MAINTENANCE ◆

⒈ When disassembling and reassembling the pump, keeping the appearance cleanness of the inner-running components to against dust. ⒉ Emptying the liquid in the pipe before taking down the pump, while inverting the pump and emptying the liquid before disassembling the pump. ⒊ If the conveying liquid is discharged form the outlet muffler, checking if the diaphragm is damaged or the fastening bolt is loosened or not.

Failure reasons Replacement Solution
Medium is discharged from exhaust muffler 1-2piece Replace diaphragm (TFE, butyronitrile)
No material discharges or small flow 2-4piece 1、Replace ball, tee, sealing ring 2、Replace inlet and outlet material pipe and box top
Not working 1piece
1
piece
1、Make sure white nylon ring of air valve closely connects with air cylinder. Under the normal condition, the connection is 0.4mm. 2、Make sure if type V sealing ring is damage or not. The gap of type V sealing ring should be outward when installation
Note:
1、Please keep clean of the component appearance before the installation, adding lubricant, keeping the balance between the box top and the plane of inlet and outlet pipe. Non-straightness is 0.05mm. The adopted method is that install the box top at first, then installs the inlet and outlet material pipe to adjust, keeping balance, locking the fastening screw. 2、Please install oil-water separator or regularly inset into oil spray from inlet pipe to cylinder, the amount don’t exceed a drop per minute.